Q.23 A batch bioreactor is to be scaled up from 10 to 10,000 liters. The diameter of the large bioreactor is 10 times that of the small bioreactor. The agitator speed in the small bioreactor is 450 rpm. Determine the agitator speed (rpm) of the large bioreactor with same impeller tip speed as that of the small bioreactor. __________

Q.23 A batch bioreactor is to be scaled up from 10 to 10,000 liters.
The diameter of the large bioreactor is 10 times that of the small
bioreactor. The agitator speed in the small bioreactor is 450 rpm.
Determine the agitator speed (rpm) of the large bioreactor with same
impeller tip speed as that of the small bioreactor.
__________

Bioreactor Scale-Up: Calculate Impeller Tip Speed & Agitator RPM

Impeller tip speed remains constant during bioreactor scale-up to maintain similar shear and mixing characteristics. For a 10-fold increase in bioreactor diameter (and thus impeller diameter), the agitator speed must decrease proportionally to 45 rpm. This ensures the peripheral velocity at the impeller tip matches the small-scale 450 rpm operation[web:8].

Correct Answer & Calculation

The agitator speed in the large bioreactor is 45 rpm.

Impeller tip speed vt follows vt = πDN/60, where D is impeller diameter and N is speed in rpm.

For constant tip speed:

πDsNs/60 = πDlNl/60

DsNs = DlNl

Given Dl = 10Ds and Ns = 450 rpm:

Nl = (Ds × 450)/(10Ds) = 45 rpm

Volume scales from 10 to 10,000 L (1,000×), but diameter ratio directly governs impeller scaling here.

Why Constant Tip Speed?

Constant tip speed preserves maximum shear stress and circulation velocity across scales, ideal for shear-sensitive cells like mammalian cultures.

  • Matches oxygen transfer and blending time in lab-to-production transitions.
  • Common criterion when geometry (impeller/tank ratio) scales geometrically.

Options Analysis (GATE Q.23)

This GATE-style question implies multiple-choice: 45, 60, 75, 90 rpm.

Option RPM Value Why Incorrect/Correct
A 45 Correct: Direct inverse proportionality to 10× diameter keeps vt constant
B 60 Incorrect: Might assume partial geometric scaling or volume1/3 (10× vol ~2.15× linear, but problem states 10× diameter).
C 75 Incorrect: No standard criterion yields this; ignores exact 10× ratio.
D 90 Incorrect: Underestimates diameter impact; perhaps confuses with constant power/volume (N ~ scale-2/3)

Scale-Up Criteria Comparison

Criterion Speed Scaling Rule Large RPM Example Use Case
Constant Tip Speed Nl = Ns(Ds/Dl) 45 rpm Shear-limited processes
Constant Re Nl = Ns(Ds/Dl)2 4.5 rpm Laminar mixing
Constant P/V Nl = Ns(Ds/Dl)2/3 ~126 rpm Turbulent power

For biotech fermentation, tip speed balances oxygen demand and cell viability.

 