Q.56 In a compound microscope, the magnification power of the objective lens is 100x, and that of the eye piece (ocular lens) is 10x. The magnification power of the microscope is _____ x.

Q.56 In a compound microscope, the magnification power of the objective lens is 100x, and that of the
eye piece (ocular lens) is 10x. The magnification power of the microscope is _____ x.

Introduction to Compound Microscope Magnification Power

Compound microscopes achieve high compound microscope magnification power by combining an
objective lens (near the specimen) and an eyepiece (ocular lens).
For a 100x objective and 10x eyepiece, the total magnification reaches 1000x,
ideal for examining cells and microorganisms in life sciences and CSIR NET exams.

How Magnification Power is Calculated

The total magnification (m) of a compound microscope is given by the product of the magnifications of the objective and eyepiece lenses:

Formula: m = mo × me

  • Objective lens: 100x — forms the first enlarged real image.
  • Eyepiece lens: 10x — magnifies this image as a virtual image.

So, the total magnification = 100 × 10 = 1000x.

Lens Marked Power Role
Objective 100x Primary magnification
Eyepiece 10x Secondary angular magnification
Total 1000x Combined magnification

Magnification Formula Derivation

The objective lens produces a real, inverted, and magnified image of the specimen.
The eyepiece acts as a simple microscope to further enlarge this image.
The detailed relation based on focal lengths is:

m = (L / fo) × (D / fe)

where L is the distance between the objective and eyepiece (tube length),
fo and fe are their focal lengths, and D is the least distance of distinct vision (25 cm).
In practical and exam contexts, magnification powers (100x and 10x) are multiplied directly.

Common Misconceptions

  • Do not add the lens powers (100x + 10x = 110x) — this is incorrect.
  • Do not divide them — total magnification is the product of both lenses.
  • Ignore focal length-based formulas unless explicitly required in derivation questions.

Applications in CSIR NET and Biology

A compound microscope with a total magnification of 1000x is used in biological laboratories to observe cells, bacteria, and chromosomes.
In competitive exams like CSIR NET, direct magnification multiplication questions often appear in the optics section.

Tips for Exam Questions

  • Always use the product rule: total magnification = objective × eyepiece.
  • Unless stated otherwise, use marked lens powers directly (e.g., 100x × 10x = 1000x).
  • Understand the concept behind real and virtual image formation.

 