3. What would be the actual size of an object that appears as 2 µm when it is magnified 1000 times? A. 2 nm B. 20 nm C. 2 mm D. 20 µm Correct […]
Tag: CSIR NET Life Science Previous Year Questions on METHODS IN BIOLOGY
Tag: CSIR NET Life Science Previous Year Questions on METHODS IN BIOLOGY
No posts found.
Function of Scanning Electron Microscopy
- admin
- January 29, 2026
- No Comments
2. Function of scanning electron microscopy (SEM) is: A. To create a sense of depth B. To examine internal cellular structure C. To observe living specimens D. Both A and […]
Electron Microscope Higher Magnification Wavelength Reason
- admin
- January 29, 2026
- No Comments
1. Why does an electron microscope give higher magnifications than an optical microscope? A. Because the electrons have more energy than light particles B. Because the velocity of electrons is […]
Protein Mixture Cation Exchange
75. A mixture of two proteins was subjected to following three chromatographic columns: (a) Cation exchange, (b) Size exclusion (Sephadex 100) and (c) Reverse phase. Following elution profiles were obtained. […]
Ultrafiltration Cannot Remove Salt Protein Solution
- admin
- January 29, 2026
- 2 Comments
74. Which one of the following techniques CANNOT be used to remove salt from a protein solution (A) Ultrafiltration (B) Ion exchange chromatography (C) Gel filtration chromatography (D) Dialysis The […]
Lectin Sepharose Right-Side-Out Vesicles
73. You are studying the binding of proteins to the cytoplasmic face of cultured liver cells and have found a method that gives a good yield of inside-out vesicles from […]
DEAE-Sephadex Chromatofocusing Phenyl Sepharose
- admin
- January 29, 2026
- 2 Comments
72. Match the chromatographic technique from Group X with the appropriate elution conditions given in Group Y: Group X A. DEAE-Sephadex B. Chromatofocusing C. Phenyl Sepharose D. G-150 Sephadex Group […]
Ion-Pairing Agents Reverse Phase Chromatography
- admin
- January 29, 2026
- 2 Comments
71. In which type of chromatography are ion-pairing agents used for elution? A. Hydrophobic interaction chromatography B. Reverse phase chromatography C. Ion exchange chromatography D. Immobilized metal anion chromatography Reverse […]
Nickel Nitrilotriacetic Acid Columns
70. Nickel nitrilotriacetic acid columns are used in __________ chromatography. A. Ion exchange B. Affinity C. Size exclusion D. Reverse phase The correct answer is B. Affinity. Nickel nitrilotriacetic acid […]
Hydrophobic Interaction Chromatography High Ionic Strength
69. Which one of the following purification steps always requires a high initial ionic strength in the sample? A. Ion exchange chromatography B. Hydrophobic interaction chromatography C. Chromatofocusing D. Gel […]


